HP Server Computers - HP Discontinued rp2400 Server
The HP 9000 rp2400 Series Servers reached end of life on Feb 1, 2005. Please consider the rp3410/rp3440 as replacement products.
The HP rp2400 series servers are rack-mounted and offer superior power and flexibility in a sleek design. The HP Servers rp2430 and rp2470 are perfect for distributed sites and branch office locations of large enterprises, and for use in small and medium-sized businesses. With the rp2430 and rp2470, you gain all the functionality and robustness of a UNIX server at the price of a PC server platform. The rp2430 and rp2470 servers evolved from HP\'s popular A-Class. These rp2400 series servers pack more performance and capability in the same compact package.
1.0 amps at maximum load with input voltage of 88 VAC and 47 Hz
Maximum Heat Dissipation
3,000 BTUs/Hour
rp2450
Input Voltage
–48/60VDC nominal
Input Current
16A, dual input
Maximum Heat Dissipation
3,000 BTUs/Hour
Environmental specifications
rp2430, rp2470
Sound power level
6.4 Bels LWA
Sound pressure level at operator position
58.2 dB LPA
rp2450
Sound power level
Less than 60dBA at a distance of 600mm and a height of 1500mm,
measured at 25C
rp2430, rp2470
Parameter
Maximum Non-Operating
Range
Temperature
Maximum Non-Operating Range: -40º to +65º C (-40º to 149º
F)
Recommended Range: 20º to 25º C (70º to 77º F)
Maximum Operating Range: 5º C to 35º C (plus or minus 2º
C)
(41º to 95º F) (plus or minus 3º F)
Rate of Change (per hour): 10º C (50º F) 20º C (68º F)
20º F (-7º C) 30º F (-1º C)
Operating Humidity
Maximum Non-Operating
Range: 5% tp 90%
non-condensing at 25º C (77º F)
Recommended Range: 40 % to 50%
non-condensing at 25º C (77º F)
Maximum Operating Range: 15% to 80%
non-condensing at 25º C (77º F)
Rate of Change (per hour): 30% RH/hour
rp2450
Parameter
Maximum Operating Range
Temperature
5ºC to 40ºC (41º F to 104ºF)
Operating Humidity
10% to 95% relative humidity, noncondensing, subject to a
maximum absolute humidity of 0.024 kg water/kg of dry air